Acron Paints


Silvacote

Description

A thin resin based aluminium protective coating of brushing consistency which dries to a silvery finish.

Uses

A light/heat reflective coating for use over bituminous coatings and primed steel. Not suitable for direct application to expanded polystyrene.

Preparation

All surfaces should be clean, dry and free from dust, dirt, oil, grease and loose material. Stir very thoroughly before use and do not thin. Apply immediately and continue stirring periodically during use.

Application

Apply two coats by brush or mohair roller, the second coat being applied as soon as the first is dry. Over recently applied bituminous surfaces allow the following minimum period to elapse after the final coat has dried before applying for Hot Applied Coatings, 24 hours and for Solvent Based Coatings, 3 days.
Over bituminous surfaces, apply the thinnest coat necessary to obliterate the black colour of the bitumen coating for the first coat. The second coat should also be thin. Avoid the formation of pools. When brushing use soft bristle brushes applying the lightest pressure.

Properties

Pack Sizes2.5, 5 and 25 litres
Cleaning of ToolsClean with paraffin (kerosene) or white spirit
Shelf Life12 months under good storage conditions in original unopened containers
StorageContainers must be kept sealed and stored under cover away from sources of heat and ignition
Type of SolventPetroleum hydrocarbons
Flash Point40°C. Test Method : BS 2000 Part 170 : 1982 (IP 170/78(81))
S G1.00
Coverage100-150m² per 25 litre dependant upon porosity of substrate
Drying TimeApprox 1 hour, depending upon temperature, humidity, air change and base conditions
Application Temp LimitsNormally 5 to 55°C
Service Temp Limits-30°C to 90°C
Chemical and Water ResistanceResistant to water and most salt solutions. Not resistant to acids, alkalis, oils and solvents

Health and Safety

Flammability
Flammable. Keep away from sources of ignition including pilot lights and sparks. Take precautionary measures against static discharge. Keep containers tightly closed when not in use. Do not Smoke. If used in an enclosed space, ensure thorough ventilation of the area (using flame proof mechanical blowers if necessary) to avoid any accumulation of vapour until the product has dried. In case of fire, use dry powder, carbon dioxide (CO²), foam, sand or earth. Never use water as this may spread the fire.

Skin Contact
Contains solvents which cause de-fatting of the skin and in extreme cases dermatitis. Avoid contact by careful working and use of barrier cream on hands, arms and other exposed areas or wear gloves. Remove skin contamination immediately with soap and water.

Eye Contact
Avoid contact. Could have an irritating effect. In the event of accidental contact, irrigate the eyes immediately with clean water for 15 minutes.

Inhalation
Contains low volatility solvent. Use in well ventilated areas and avoid inhalation.

Oral Ingestion
With proper handling, this should not occur. The possibility can be minimized by not consuming food in the working area and by washing hands prior to eating, smoking or drinking.

Spillage
Spilt material should be mopped up immediately with an inert, absorbent material such as sand and disposed of in accordance with regulations.

Disposal of Containers
Do not leave containers on site where residue could be a hazard to children, animals or the environment. Replace lids and remove to a central disposal point.

Product Reference No. SILV. Issue Date August 2002

Aluminium Reflective Coating

Acron Paints
Unit 6, William Street, Northam, Southampton, Hampshire, SO14 5QH
Tel: 023 80223266sales@acronpaints.co.ukFax: 08700 527 587

The claims made in this document are made in good faith and are based on exhaustive tests carried out over a long period.
Acron Paints, their agents and their distributors cannot accept any liability for the behaviour of their materials in individual cases.

A printer friendly copy is available here A Health and Safety Reference Datasheet is available here