Acron Paints

Acron Paints, Unit 6 William Street, Northam, Southampton, Hants. S014 5QH
Tel: 023 80 223266 Fax: 08700 527587

Material Safety Data SheetRevision No.2/2002
 
Suppliers Name and Address:
Acron Paints
Unit 6, William Street, Northam
Southampton, Hants. S014 5QH
Tel: 023 80 223266 Fax: 08700 527587
Product Name/s:
Aeromatic Aerosols
  1. Identification of Substance

    Aeromatic Aerosols.

  2. Composition/Information on Ingredients

    AcetoneCas No.67-64-1Contents10 to 30%
    ButanoneCas No.78-93-3Contents10 to 30%Health (class)XiRisk (R.No.)36/37
    Dimethyl EtherCas No.115-10-6Contents30 to 60%

  3. Hazards Identification

    Extremely flammable. Irritating to eyes.

  4. First Aid Measures

    General : In all cases of doubt or when symptoms persist, seek medical attention. Never give anything by mouth to an unconscious person.

    Inhalation : Remove victim immediately from source of exposure. Move the exposed person to fresh air at once. When breathing is difficult, properly trained personnel may assist affected person by administering 100% oxygen. Keep the affected person warm and at rest. Seek prompt medical attention.

    Ingestion : Not relevant.

    Skin : Remove contaminated clothing. Wash the skin immediately with soap and water. Seek medical attention if discomfort continues.

    Eyes : Make sure to remove any contact lenses from the eyes before rinsing. Continue to rinse for at least 15 minutes. Contact physician if irritation persists. Get medical attention promptly if symptoms occur after washing.

  5. Fire Fighting Measures

    Extinguishing Media : Use powder, dry chemicals, sand, dolomite etc. Water spray, fog or mist.

    Special Fire Fighting Procedures : Containers close to fire should be removed or cooled with water. Use water to keep fire exposed containers cool and disperse vapours.

    Unusual Fire and Explosion Hazards : Aerosol cans may explode in fires. Risk of explosion if heated.

  6. Accidental Release Measures

    Spill Cleanup Methods : Extinguish all ignition sources. Avoid sparks, flames, heat and smoking. Ventilate. Wear necessary protective equipment. If leakage cannot be stopped, evacuate area and ventilate well.

    Larger Spill : Do not contaminate water sources or sewers.

  7. Handing and Storage

    Usage Precautions : Keep away from heat, sparks and open flame. Provide good ventilation. Read and follow manufacturers recommendations.

  8. Exposure Controls and Personal Protection

    Engineering Measures : Provide adequate ventilation. Where reasonably practicable, this should be achieved by the use of local exhaust ventilation and good general extraction. If extraction methods are insufficient to maintain concentrations of particles and/or solvent vapours below relevant OEL's suitable respiratory protective equipment should be worn.

    Ingredient Name:CAS No:STDLT Exp. - 8 hoursLT Exp - 10 minutes
    Acetone67-64-1OES750ppm1500ppm
    Butanone78-93-3OES200ppm (sk)300ppm (sk)
    Dimethyl Ether115-10-6OES400ppm500ppm
     
    Ingredient CommentOES Occupational Exposure Standard
     Sk Can be absorbed through the skin.

    Ventilation : Provide adequate general and local exhaust ventilation. All handling to take place in well ventilated area.

    Protective Gloves : Chemical resistant gloves required for prolonged or repeated contact.

    Eye Protection : Wear approved chemical safety goggles where eye exposure is probable.

    Other Protection : Wear appropriate clothing to prevent any possibility of liquid contact and repeated or prolonged vapour contact.

    Hygienic Work Routines : Do not smoke in work area. Wash at the end of each shift and before eating, smoking and using the toilet. Remove any contaminated clothing.

  9. Physical and Chemical Properties

    AppearanceAerosol
    ColourColourless
    Lower Flammability Limit0.8%
    Upper Flammability Limit13%
    Odour / TasteOrganic Solvents

  10. Stability and Reactivity

    Stability : Normally stable. Conditions to avoid : Avoid heat, flames and other sources or ignition. Avoid contact with strong oxidising agents, strong alkalis, strong mineral acids.

    Hazardous Decomposition Products : Fire creates vapours / gasses / fumes of carbon monoxide (CO), Carbon dioxide (CO2).

  11. Toxiclogical Information

    Health Hazards / General : Prolonged and repeated contact with solvents over a long period may lead to permanent health problems.

    Inhalation : Gas or vapour in high concentrations may irritate respiratory system. Gas or vapour displaces oxygen available for breathing (asphyxiant).

    Skin : Irritant to skin. Prolonged or repeated exposure may cause severe irritation.

    Eyes : Spray and vapour in the eyes may cause irritation and smarting.

    Route of Entry : Inhalation, skin and eye contact.

  12. Ecological Information

    Environmental Hazards : No negative effects on the aquatic environment are known.

  13. Disposal Considerations

    Disposal Methods : Empty containers must not be burned due to explosion hazards. Dispose of in accordance with Local Authority requirements.

  14. Transport Information

    Road/Rail
    UN Number1950 ADR Item No.5F Marginal2201
    Hazchem CodeN/A EDIFC TEC R. No.20G27-2 Proper Shipping NameAerosols
    Note: Exempt from control as Limited Quantity provisions apply.
    Rail
    Transport Class No.2 Railroad PT5F
    Sea
    UN Sea No.1950 Transport Class No.2 IMDG Page No.2102
    Sea Pack GRN/A EMs No.2-13 MFAG Table No.620
    Marine PollutantNo
    Air
    UN Air No.1950 Transport Class No.2.1 Air Sub ClassN/A
    Air Pack GRN/A

  15. Regulatory Information

    Label for supply : Extremely flammable. Irritant.

    Risk Phrases

    R-12 Extremely flammable
    R-37/37 Irritating to eyes and respiratory system.

    Safety Phrases

    S-2 Keep out of reach of children
    S-16 Keep away from sources of ignition
    S-25 Avoid contact with eyes
    S-26 in case of contact with eyes, rinse immediately with water
    S-51 Use only in well ventilated areas
    S-23A Do not breathe vapour or spray.

    UK Regulatory References : Petroleum (Consolidation) Act, as amended 1984 SI 1244. Highly flammable Liquid Regulations 1972.

    UK Environmental Listings : Rivers (prevention of pollution) Act 1961. Control of pollution (special waste regulations)Act 1980.

    EC Directives : System of specific information relating to Dangerous Preparations 91/155.

    Approved Code of Practice : Classification and Labeling of Substances and preparations dangerous for supply.

    Guidance Notes : OELS : EH40. Introduction to local exhaust ventilation HS(G)37. CHIP for everyone HSG(108).

  16. Other Information - Dangerous Properties of Industrial Materials Report. N.Sax et .al. The information contained in this safety data sheet is provided in accordance with the requirements of the Chemicals (Hazard Information and Packaging) Regulations. The product should not be used for purposes other than those shown in Section 1 without first referring to the supplier and obtaining written instructions. As the specific conditions of use of the product are outside of the suppliers control, the user is responsible for ensuring that the requirements of relevant legislation are complied with. The information contained in this safety data sheet is based on the present state of knowledge and current national legislation. It provides guidance on health, safety and environmental aspects of the product and should not be construed as any guarantee of technical performance or suitability for particular applications.

Acron Health and Safety

A printer friendly copy is available here A Technical Reference Datasheet is available here